Our apparatus for this experiment consists of a few main components.
Laser block
We will be assembling
The most important part of configuring the PID controller is setting the constants . We will be following the Ziegler-Nichols method for tuning.
Turn off the Integral and Derivative components for the controller; only use Proportional control
Slowly increase the gain (i.e., ) until the process starts to oscillate. Measure the final gain value is known as ; and the period of oscillation as .
We can set the PID variables using the following table
Controller | K_p | K_i | K_d |
---|---|---|---|
Piezo Driver - Link
TEC and laser driver - Link
https://www.crystalinstruments.com/blog/2020/8/23/pid-control-theory
P
K_u / 2
PI
K_u / 2.5
T_u / 1.25
PID
0.6 K_u
T_U / 2
T_u / 8